- 1, 2, 3, 4 working wavelengths (1310/1383/1490/1550/1625 nm) per module
- Modules for single-mode and multi-mode OV
- Very small value of the dead zone (up to 0.8 m in attenuation)
- The function of automatic bidirectional measurement of parameters
- Allows you to automate the measurement process
- Checking the integrity of the OV
- Ensures data transfer through OB
- Measurement of real attenuation at the OB welding point using two-way testing
Polarization-mode dispersion analysis module:
- Correspondence of rivers. ITU-T G.650.2, EIA / TIA FOTP-113, IEC 60793-1-48
- Fast and reliable method of measuring polarization-mode dispersion
- High measurement accuracy using the Fourier transform
- Measurements using a source of polarized radiation and a receiver
- High dynamic range using a handheld broadband emitter: > 55 dB
- Wide measurement range with the minimum possible DGD value (0.08 ps)
- Fast measurement time: from 6 seconds
- Ability to measure across multiple installed EDFAs
- Function of long-term monitoring and collection of statistics
Chromatic dispersion analysis module:
- Correspondence of rivers. ITU-T G.650.1, EIA / TIA FOTP-175-B, IEC 60793-1-42
A fast and reliable method of measuring chromatic dispersion
Measurements using one device
Measurement of dispersion in separate sections of the OV
Measuring the entire length of the OB in 45 seconds
Wide range of wavelengths (from 1250 to 1650 nm), wide measuring range
Dynamic range> 50 dB
Optical loss measurement module:
- Wavelengths 1310/1550/1625 nm
- Additional optical power meter
- Built-in radiation source for manual insertion loss measurement (also compatible with TwinTest function)
- Measurement of optical return loss (ORL) in manual mode using one device
- Testing in automatic mode
- Integrity of the optical fiber
- Bidirectional measurement of input losses and return losses
- A better solution for testing FTTX
CWDM / DWDM test module:
- High accuracy of wavelengths without the need for external calibration
- Fast test time: 1.5 seconds to scan the entire strip
- Built-in source for calibration
- Channel isolation for BER testing
- Patented two-channel analyzer
WDM, PMD, AP testing module:
- Full range WDM testing. The range of wavelengths is 1260 ... 1640 nm
- High performance PMD test module with DGD measurement in the range from 0.08 to 60 ps and 45 dB dynamic range
- Attenuation profile testing with measurement of total loss and dB/km values in the wavelength range 1260 ... 1640 nm and a dynamic range of 45 dBth range 1260 ... 1640 nm and a dynamic range of 45 dB